CG450-1560 CycleGard Low Water Cutoff for Steam Boilers w/ 15 Minute Intermittent Level Test - 120V (45-460-1560)

Price
Request a Quote
Stock
In Stock

Intermittent Level Test – Maximum Protection for Foaming Boilers

  • 15 Second Burner Off Delay
  • 30 Second Burner On Delay
  • Automatic Reset
  • Low Water Indicating Light
  • Direct Boiler Mounting – Eliminates Blowdowns Burner circuit contacts open after 15 second delay in a low water condition. Delay prevents short cycling caused by momentary fluctuations in the boiler water level. Automatically reactivates burner circuit 30 seconds after water reaches the probe, allowing optional water feeder to raise water level above the probe. Intermittent Level Test (ILT) feature provides maximum boiler protection by removing power from the burner circuit at set intervals. 

    This model performs the Intermittent Level Tests every 15 minutes for 60 seconds.
  • Replaces CG450-2060
  • Replaces GC450-1090

 

Documentation

Similar SKUs

7505A-0000
7505A-0000
OIL PRIMARY
R.W. Beckett
Request a Quote
In Stock 10 - 20 days
GeniSys Cad Cell Oil Primary Control (Replaces R8184G Relay Controls) NO Pre-Purge/ No-Post-Purge
7505B-1500U
7505B-1500U
OIL PRIMARY
R.W. Beckett
Request a Quote
In Stock 10 - 20 days
GeniSys Cad Cell Oil Primary Control w/ 15 sec Pre-Purge (Replaces R7184B Relay Controls)
47-2
47-2
#47-2 Mechanical Water Feeder w/Quick Hook Up Fittings for Steam & Hot Water Boilers with Cold Water Feed and Low Water Cut Off (Part Number 132800)
McDonnell & Miller
Request a Quote
Out of Stock
#47-2 Mechanical Water Feeder w/Quick Hook Up Fittings for Steam & Hot Water Boilers with Cold Water Feed and Low Water Cut Off (Part Number 132800)
450
450
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
Hydrolevel
Request a Quote
In Stock
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
400
400
400 Non-Cycling Primary Low Water Cut-Off for Steam Boilers with Automatic Reset 24V
Hydrolevel
Request a Quote
In Stock
400 Non-Cycling Primary Low Water Cut-Off for Steam Boilers with Automatic Reset 24V
500
500
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
Hydrolevel
Request a Quote
Out of Stock
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
550
550
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
Hydrolevel
Request a Quote
In Stock
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
650
650
650 Low Water Cutoff for Water Boilers w/ Auto Reset & Test Button/Light - 120V (45-650)
Hydrolevel
Request a Quote
Out of Stock
650 Low Water Cutoff for Water Boilers w/ Auto Reset & Test Button/Light - 120V
show more