400 Non-Cycling Primary Low Water Cut-Off for Steam Boilers with Automatic Reset 24V

Price
Request a Quote
Stock
In Stock

 

  • Reliable Electronic Operation
  • Easy to Install
  • Low Maintenance; No Blowdowns
  • No Moving Parts to Wear or Stick
  • Time Delay Prevents Burner Short Cycling
  • Inexpensive to Own and Operate
  • 15 Second Burner Off Delay
  • 30 Second Burner On Delay
  • Automatic Reset
  • Low Water Indicating Light
  • Direct Boiler Mounting Eliminates Blowdowns


Operation:
Burner circuit contacts open after 15 second delay in a low water condition. Delay prevents short cycling caused by momentary fluctuations in the boiler water level. Automatically reactivates burner circuit 30 seconds after water reaches the probe, allowing optional water feeder to raise water level above the probe.

Hydrolevel low water cut-offs are electrically operated. A probe is installed in the boiler shell or external manifold and is connected to the control unit. Water is used as a conductor to complete the circuit between the probe and the boiler shell. When water is in contact with the probe, the circuit is completed; when the water level drops below the probe, the circuit opens. Hydrolevel controls provide contacts to de-energize the burner circuit in a low water condition.

Can Replace Mcdonnell Miller

          PS802-24 (153917)

          PSE802-24 (153927)

 

Specifications

Specifications

  • Application: Steam Boilers Switch: SPDT Max Pressure (PSI): 15 (Steam) Type: Electronic Reset Type: Automatic Voltage: 24v Power Consumption: 2 VA Burner On Delay: 30 Second Burner Off Delay: 15 Second Aux Switch Ratings: 50 VA pilot duty @ 24 V

Similar SKUs

NO. 11
NO. 11
NO. 11 Switch for Series 61, 64, 67 69 and 70 Low Water Cut Off (309100)
McDonnell & Miller
Request a Quote
Out of Stock
NO. 11 Switch for Series 61, 64, 67 69 and 70 Low Water Cut Off
#51
#51
#51 Mechanical Water Feeder for Low Pressure Steam and Hot Water Boilers (134700)
McDonnell & Miller
Request a Quote
Out of Stock
#51 Mechanical Water Feeder for Low Pressure Steam and Hot Water Boilers
WFE-24V
WFE-24V
WFE-24V Electronic Water Feeder, 120V 3/8" (Part Number 169550)
McDonnell & Miller
Request a Quote
In Stock
WFE-24V Electronic Water Feeder, 120V 3/8" (Part Number 169550)
450
450
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
Hydrolevel
Request a Quote
In Stock
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
500
500
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
Hydrolevel
Request a Quote
Out of Stock
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
550
550
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
Hydrolevel
Request a Quote
In Stock
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
650
650
650 Low Water Cutoff for Water Boilers w/ Auto Reset & Test Button/Light - 120V (45-650)
Hydrolevel
Request a Quote
Out of Stock
650 Low Water Cutoff for Water Boilers w/ Auto Reset & Test Button/Light - 120V
CG450-1560
CG450-1560
CG450-1560 CycleGard Low Water Cutoff for Steam Boilers w/ 15 Minute Intermittent Level Test - 120V (45-460-1560)
Hydrolevel
Request a Quote
In Stock
CG450-1560 CycleGard Low Water Cutoff for Steam Boilers w/ 15 Minute Intermittent Level Test - 120V (45-460-1560)
show more