Hydrolevel low water cut-offs are electrically operated. A probe is installed in the boiler shell or external manifold and is connected to the control unit. Water is used as a conductor to complete the circuit between the probe and the boiler shell. When water is in contact with the probe, the circuit is completed; when the water level drops below the probe, the circuit opens. Hydrolevel controls provide contacts to de-energize the burner circuit in a low water condition.

Hydrolevel low water cut-offs are electrically operated. A probe is installed in the boiler shell or external manifold and is connected to the control unit. Water is used as a conductor to complete the circuit between the probe and the boiler shell. When water is in contact with the probe, the circuit is completed; when the water level drops below the probe, the circuit opens. Hydrolevel controls provide contacts to de-energize the burner circuit in a low water condition.

Specifications

Specifications

  • Application: Hot Water Boilers Switch: SPDT Max Pressure (PSI): 160 Type: Electronic Reset Type: Automatic Voltage: 120v Power Consumption: 4 VA

Similar SKUs

NO. 11
NO. 11
NO. 11 Switch for Series 61, 64, 67 69 and 70 Low Water Cut Off (309100)
McDonnell & Miller
Request a Quote
1 In Stock
NO. 11 Switch for Series 61, 64, 67 69 and 70 Low Water Cut Off
WFE-24V
WFE-24V
WFE-24V Electronic Water Feeder, 120V 3/8" (Part Number 169550)
McDonnell & Miller
Request a Quote
2 In Stock
WFE-24V Electronic Water Feeder, 120V 3/8" (Part Number 169550)
400
400
400 Non-Cycling Primary Low Water Cut-Off for Steam Boilers with Automatic Reset 24V
Hydrolevel
Request a Quote
Out of Stock
400 Non-Cycling Primary Low Water Cut-Off for Steam Boilers with Automatic Reset 24V
450
450
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
Hydrolevel
Request a Quote
1 In Stock
450 Non-Cycling Steam Primary Low Water Cutoff - 120V (45-450)
500
500
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
Hydrolevel
Request a Quote
Out of Stock
500 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 24V (45-500)
550
550
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
Hydrolevel
Request a Quote
2 In Stock
550 Low Water Cutoff for Water Boilers w/ Manual Reset & Test Button/Light - 120V
CG450-1560
CG450-1560
CG450-1560 CycleGard Low Water Cutoff for Steam Boilers w/ 15 Minute Intermittent Level Test - 120V (45-460-1560)
Hydrolevel
Request a Quote
1 In Stock
CG450-1560 CycleGard Low Water Cutoff for Steam Boilers w/ 15 Minute Intermittent Level Test - 120V (45-460-1560)
VXT-120
VXT-120
VXT-120 Water Feeder, 120V With Digital Feed Counter (Part Number 45-122)
Hydrolevel
Request a Quote
2 In Stock
VXT-120 Water Feeder, 120V With Digital Feed Counter (Part Number 45-122)