CARLIN OIL PRIMARY CONTROLS

Brand: Carlin Combustion Technology, Inc
Does not ship to OH, United States

CARLIN OIL BURNER PRIMARY CONTROL 120V

Models matching criteria: 6
KlWY/SkuImages/e31f59f2-4a78-4dec-82f0-5e4186374905/CARLIN-60200.jpeg
Oil Primary Control (0-Pre-Purge/15 TFI/0-Post-Purge. Interrupted Duty.) view more
Oil Primary Control 
NO PRE-PURGE
NO POST-PURGE
15 SEC TRIAL FOR IGNITION
INTERRUPTED DUTY. 
Does not have Alarm Contacts)
In Stock 10 - 20 days
Does not ship to OH, United States
CARLIN CONTROL 48245.png
OIL BURNER PRIMARY 0-Pre-Purge/0-Post-Purge 15 OR 45 SEC TFI view more
  • OIL BURNER PRIMARY  
  • NO PRE-PURGE
  • NO POST-PURGE
  • 15 OR 45 SECOND TRIAL FOR IGNITION
  • Intermittent Duty Ignition 
  • Red LED Lockout Indicator
  • Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology
  • Power Input (From Limit Circuit) 120 vac, 60 Hz, 10 VA Motor Load 5 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA
  • Operating Temperature Limits + 32°F to + 140°F
  • Storage Temperature Limits -40°F to +185°F
  • Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS
In Stock 10 - 20 days
Does not ship to OH, United States
KlWY/SkuImages/beaaf53c-e87c-45c9-a9f3-08cebb8f452b/CARLIN-60200.jpeg
Oil Primary Control (0-Pre-purge/15 TFI/0- Post-purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control
NO PRE PURGE
NO POST-PURGE
15 SEC. TRIAL FOR IGNITION
INTERRUPTED DUTY
INCLUDES ALARM CONTACTS 
  • Interrupted Duty Ignition Recycle on Flame Failure
  • Serviceman Reset Protection ( Latch-up after three consecutive lockouts)
  • Diagnostic LED's
  • 15 Second Trial for Ignition (TFI)
  • 1.3 Second Flame Failure response time (FFRT)
  • Alarm Contacts
  • Thermostat/aquastat Compatible
  • SMC (Safety Monitoring Circuit) Technology
  • Power Input (From Limit Circuit) 120 vac, 60 Hz, 9 VA
  • Motor Load 10 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA Alarm Contacts 24 V, AC/DC, 2 A
  • Operating Temperature Limits + 32°F to + 140°F
  • Storage Temperature Limits -40°F to +185°F
  • Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS
Hide Description
In Stock 10 - 20 days
Does not ship to OH, United States
KlWY/SkuImages/0555e877-96c6-4e6c-b18e-2cc881f35a9b/CARLIN-60200.jpeg
Oil Primary Control (15 Pre-purge/15 TFI/15 Post-Purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control 
15 Sec Pre-purge
15 Sec. Post-Purge
15 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
In Stock 10 - 20 days
Does not ship to OH, United States
KlWY/SkuImages/74c1b20f-4e7e-46e8-a237-cc0adf01c74b/CARLIN-60200.jpeg
Oil Primary Control (30 Pre-purge/15 TFI/30 Post-Purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control 
30 Sec Pre-purge
15 Sec. Post-Purge
30 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
In Stock
Does not ship to OH, United States
KlWY/SkuImages/e0637253-2b35-487a-8703-8f6691e70721/70200.jpg
CARLIN UNIVERSAL OIL PRIMARY CONTROL view more
  • Replaces virtually any oil primary control 
  • Pinpoints cause of burner faults for fast, accurate repairs 
  • 3 different ignition options (Smart, Interrupted and Intermittent) • Last Fault Alert – Displays fault reason even if homeowner resets control
  • Larger LCD Display – Straightforward fault messages with no codes to decipher 
  • Simple Setup – “Plug and Play” on your favorite application 
  • Recessed Wiring Terminals – Added wiring space in j-box 
  • Low Voltage Blocked Vent Contacts – Allows for easy connection
In Stock
Does not ship to OH, United States

PRIMARY CONTROL FOR OIL BURNER 120V

show more