OIL PRIMARY

Brand: R.W. Beckett Corporation
Does not ship to Ohio, United States

The Beckett GeniSys® 7505 Oil Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys® 7505 is used with the to control the oil burner’s motor, igniter, and optional solenoid valve. It has front-mounted, 24 VAC thermostat terminals compatible with both mechanical and many power stealing thermostats. The control operates the burner with interrupted ignition with a 15 second lockout time.

With the or the new , the control can be programmed with pre-purge and post-purge timings. For diagnostics, the GeniSys® 7505 stores the last 15 cycles.

For high moisture environments, a potted version is offered in the .

3 models matching criteria
KlWY/SkuImages/3ce13d19-ff53-4981-8898-87418aaefcfa/Beckett-GeniSys-7505-120V-Oil-Burner-Control-top-right-min.jpg
GeniSys Cad Cell Oil Primary Control (Replaces R8184G Relay Controls) NO Pre-Purge/ No-Post-Purge show more
7505A Advanced Burner Control is the Beckett direct replacement for R8184G controls on older Beckett burners without solenoid valves. This version has 0 seconds Pre-purge and 0 seconds post-purge. Other versions available see Models and Cross Reference Guide in Manuals section.

The 7505A can be programed with pre-purge and post-purge and cycle history read using the GeniSys Contractor tool.


The Beckett GeniSys™ Advanced Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

  • Water Resistant

  • Thermostat and boiler control compatible

  • Three status lights for system monitoring and diagnostics

  • Welded relay protection with redundant motor relays

  • Limited reset and limited recycle

  • Technician Pump Prime mode

  • 5-Year Warranty

  • 7505A0000 replaces Honeywell R8184G

  • Two communication ports for adding alarm contacts and programming tool.

  • Lockout time (TFI) – 15 seconds

  • Pre-purge – 0 seconds

  • Post-purge – 0 seconds

  • Customizable pre-time and post-time using Contractor Tool 52082U


  • Hide Description
    In Stock 10 - 20 days
    Does not ship to Ohio, United States
    KlWY/SkuImages/a94312a7-45a5-4374-97e5-b3c33467286c/Beckett-GeniSys-7505-120V-Oil-Burner-Control-top-right-min.jpg
    GeniSys Cad Cell Oil Primary Control w/ 15 sec Pre-Purge (Replaces R7184B Relay Controls) show more
    7505B Advanced Burner Control is the Beckett direct replacement for R7184B controls on Beckett burners. This version has 15 seconds Pre-purge and 0 seconds post-purge. Other versions available see Models and Cross Reference Guide in Manuals section.

    The 7505B can be programed with pre-purge and post-purge and cycle history read using the GeniSys Contractor tool.


    The Beckett GeniSys™ Advanced Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

  • Water Resistant

  • Thermostat and boiler control compatible

  • Three status lights for system monitoring and diagnostics

  • Welded relay protection with redundant motor relays

  • Limited reset and limited recycle

  • Technician Pump Prime mode

  • 5-Year Warranty

  • 7505A0000 replaces Honeywell R8184G

  • Two communication ports for adding alarm contacts and programming tool.

  • Lockout time (TFI) – 15 seconds

  • Pre-purge – 15 seconds

  • Post-purge – 0 seconds

  • Customizable pre-time and post-time using Contractor Tool 52082U


  • Hide Description
    In Stock 10 - 20 days
    Does not ship to Ohio, United States
    KlWY/SkuImages/99a495d3-417e-4984-99ff-da13e810b831/Beckett-GeniSys-7505-120V-Oil-Burner-Control-top-right-min.jpg
    GeniSys Cad Cell Oil Primary Control w/ 15 sec Pre-Purge/15 Sec Post-Purge show more
    r heater applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

    Features & Benefits:
    • Water Resistant
    • Thermostat and boiler control compatible
    • Customizable pre-time and post-time
    • Three status lights for system monitoring and diagnostics
    • Welded relay protection with redundant motor relays
    • Limited reset and limited recycle
    • Sleek, modern design
    • Technician Pump Prime mode
    • 5-Year Warranty
    • 7505a replaces Honeywell R8184G
    • 7505b replaces Honeywell R7184B
    • Two communication ports for adding alarm contacts, programming display, and/or future wireless communications
    Hide Description
    In Stock 10 - 20 days
    Does not ship to Ohio, United States

    show more