CARLIN UNIVERSAL GAS PRIMARY
Carlin 60200FRS Flame Rod Gas Burner Primary Control for EZ-Gas, EZ-Gas Pro, 201GAS, 301 GAS and 601GAS Burners. Now with LCD Screen!
Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 6020002FR943S
Features- On-Board LCD Screen: Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information
- Fault History records last 50 fault cycles to aid the technician in troubleshooting
- Field Settable Timings
- Pre-purge (0, 10, 30, 90)
- Trial for Ignition Time (4, 6)
- Post-Purge (0, 10, 15, 30, 60, 120)
- Number of Recycles allowed (0, 1, 3)
- Serviceman Reset Protection (3)
- Low Voltage Terminals TT (can be programmed as Used or Not used) Blocked Vent input (contact closure, functions as a low voltage limit) CO input (contact closure) required to start C.F.H .
- Lockout if not detected during run Alarm output (dry contacts) 24VAC/DC