Single Stage, 24 Vac, Standard Opening, Direct Ignition Gas Valve. 1/2 x 3/4". Set 3.5" WC

Price
Request a Quote
Stock
In Stock
Does not ship to OH, United States

Specifications

Dimensions

  • 5-3/8 in. high x 4-1/16 in. wide x 2-11/16 in. deep
  • 135 mm high x 104 mm wide x 69 mm deep

Includes

  • 3/4" Straight Flange; Natural to LP Conversion Kit; 3/4" x 1/2" reducer bushing;

Mounting

  • 0° to 90° in any direction from the upright position of the gas control knob, including vertically.

Frequency

  • 60 Hz

Approvals, Underwriters Laboratories Inc.

  • UL Component Recognized MCCZ2.MH5323

Approvals, Canadian Standards Association

  • CSA International: 112395

Electrical Connections

  • 1/4 in. quick-connect male terminals

Voltage

  • 24 Vac

Operating Temperature Range

  • -40° to +175° F
  • -40° to +79° C

Body Pattern

  • Straight-through

Opening Characteristics

  • Standard Opening

Pressure Ratings

  • 1/2 psi
  • 3.5 kPa

Inlet/Outlet Size

  • 3/4 in. x 3/4 in.

Pilot Gas Outlet

  • None

Pressure Tapping

  • 1/8 in. NPT with plug

Type of Fuel

  • Natural

Capacity

  • At 1 inH₂O p.d. - 270,000 BTUh: 30,000 BTUh minimum: 370,000 BTUh maximum Natural Gas

Pressure Regulator

  • Standard

Pressure Regulator Setpoint

  • 3.5 inH₂O
  • 0.87 kPa

Ignition Type

  • Direct Ignition
show more